DRA-60-24
- Universal AC Input / Full range
- Protections: Short Circuit / Overload / Over Voltage
- Can Be Installed On DIN Rail TS-35/7.5 Or 15
- Output Voltage Adjustable Through Internal Potentiometer
- Output Current Adjustable Through External 1~10Vdc, PWM Signal Or Resistance
- Cooling By Free Air Convection
- Pass LPS
- LED Indicator For Power On
- 100% Full Load Burn-In Test
- 3 Years Warranty
SPECIFICATION | ||
MODEL | DRA-60-24 | |
OUTPUT | DC VOLTAGE | 24V |
CONSTANT CURRENT REGION | 3 ~ 24V | |
RATED CURRENT | 2.5A | |
CURRENT RANGE | 0 ~ 2.5A | |
RATED POWER | 60W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | |
VOLTAGE ADJ. RANGE | 24 ~ 30V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±0.5% | |
SETUP, RISE TIME Note.4 |
400ms, 90ms/230VAC 800ms, 90ms/115VAC at full load |
|
HOLD UP TIME (Typ.) |
50ms/230VAC 10ms/115VAC at full load |
|
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-) |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 87% | |
AC CURRENT (Typ.) |
1.3A/115VAC 0.8A/230VAC |
|
INRUSH CURRENT (Typ.) |
COLD START 30A/115VAC 60A/230VAC |
|
PROTECTION | OVERLOAD | 95 ~ 108% rated output power |
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 28.98 ~ 37.26V | |
Protection type : Shut down o/p voltage, re-power on to recove | ||
ENVIRONMENT | WORKING TEMP. | 30 ~ +70°C (Refer to "Derating Curve") |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ +85°C, 10 ~ 95% RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) on output | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |
SAFETY &EMC(Note 5) | SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | |
EMC EMISSION | Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61204-3, light industry level, criteria A | |
OTHERS | MTBF | 436.4K hrs min. MIL-HDBK-217F (25°C) |
DIMENSION | 40*90*100mm (W*H*D) | |
PACKING | 0.3Kg; 42pcs/13.6Kg/0.82CUFT | |
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on http://www.meanwell.com) 6. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended |