MDR-60-24
- Universal AC input/Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- Class I Div 2 Hazardous Locations T4
- LED indicator for power on
- DC OK relay contact
- No load power consumption<0.75W
- 100% full load burn-in test
- 3 years warranty
| SPECIFICATION | ||
| MODEL | MDR-60-24 | |
| OUTPUT | DC VOLTAGE | 24V |
| RATED CURRENT | 2.5A | |
| CURRENT RANGE | 0 ~ 2.5A | |
| RATED POWER | 60W | |
| RIPPLE & NOISE (max.) Note.2 | 150mVp-p | |
| VOLTAGE ADJ. RANGE | 24 ~ 30V | |
| VOLTAGE TOLERANCE Note.3 | ±1.0% | |
| LINE REGULATION | ±1.0% | |
| LOAD REGULATION | ±1.0% | |
| SETUP, RISE TIME Note.5 |
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load |
|
| HOLD UP TIME (Typ.) |
50ms/230VAC 20ms/115VAC at full load |
|
| INPUT | VOLTAGE RANGE |
85 ~ 264VAC 120 ~ 370VDC |
| FREQUENCY RANGE | 47 ~ 63Hz | |
| EFFICIENCY (Typ.) | 88% | |
| AC CURRENT (Typ.) |
1.8A/115VAC 1A/230VAC |
|
| INRUSH CURRENT (Typ.) |
COLD START 30A/115VAC 60A/230VAC |
|
| LEAKAGE CURRENT | <1mA / 240VAC | |
| PROTECTION | OVERLOAD | 105 ~ 150% rated output power |
| Protection type :Constant current limiting, recovers automatically after fault condition is removed | ||
| OVER VOLTAGE | 31.2 ~ 36V | |
| Protection type: Shut down o/p voltage, re-power on to recover | ||
| FUNCTION | DC OK SIGNAL | Relay contact rating (max.): 30V/1A resistive |
| ENVIRONMENT | WORKING TEMP. | -20 ~ +70°C (Refer to "Derating Curve") |
| WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |
| STORAGE TEMP., HUMIDITY | -40 ~ +85°C, 10 ~ 95% RH | |
| TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | |
| VIBRATION | Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6 | |
| SAFETY &EMC (Note 4) | SAFETY STANDARDS | UL508, UL62368-1, TUV EN62368-1, Class I, Div. 2 Group A, B, C, D Hazardous Locations T4,EAC TP TC 004BSMI CNS14336-1, AS/NZS 60950.1 approved |
| WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25/ 70% RH°C | |
| EMC EMISSION | Compliance to EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class B | |
| EMC IMMUNITY | Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A, EAC TP TC 020 | |
| OTHERS | MTBF | 299.2K hrs min. MIL-HDBK-217F (25°C) |
| DIMENSION | 40*90*100mm (W*H*D) | |
| PACKING | 0.33Kg; 42pcs/14.8Kg/0.82CUFT | |
| NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on http://www.meanwell.com) 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 6.The ambient temperature derating of 3.5°C /1000m with fanless models and of 5°C /1000m with fan models for operating altitude higher than 2000m (6500ft). ※ Product Liability Disclaimer For detailed information, please refer to:https://www.meanwell.com/serviceDisclaimer.aspx |
|