DRC-100A
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Battery low / Battery reverse polarity protection protection by fuse
- Can be installed on DIN rail TS-35/7.5 or 15
- Alarm signal for AC OK and Battery low (via relay)
- Cooling by free air convection
- LED indicator for power on
- 100% full load burn-in test
- 3 years warranty
SPECIFICATION | |||
MODEL | DRC-100A | ||
OUTPUT | OUTPUT NUMBER | CH1 | CH2 |
DC VOLTAGE | 13.8V | 13.8V | |
RATED CURRENT | 4.5A | 2.5A | |
CURRENT RANGE | 0 ~ 7A | -------- | |
RATED POWER | 96.6W | ||
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | -------- | |
VOLTAGE ADJ. RANGE | CH1:12 ~ 15V | ||
VOLTAGE TOLERANCE Note.3 | ±1.0% | -------- | |
LINE REGULATION | ±0.5% | -------- | |
LOAD REGULATION | ±0.5% | -------- | |
SETUP, RISE TIME Note.4 |
2400ms, 50ms/230VAC 2400ms, 50ms/115VAC at full load |
||
HOLD UP TIME (Typ.) |
50ms/230VAC 10ms/115VAC at full load |
||
INPUT | VOLTAGE RANGE |
90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)] |
|
FREQUENCY RANGE | 47 ~ 63Hz | ||
EFFICIENCY (Typ.) | 87% | ||
AC CURRENT (Typ.) |
1.8A/115VAC 1.1A/230VAC |
||
INRUSH CURRENT (Typ.) |
COLD START 30A/115VAC 60A/230VAC |
||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power | |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||
OVER VOLTAGE | CH1:14.49 ~ 18.63V | ||
Protection type : Shut down o/p voltage, re-power on to recove | |||
BATTERY CUT OFF | 10±0.5V | ||
FUNCTION | AC OK | Relay contact output, ON : AC OK ; OFF : AC Fail ; max. rating : 30V/1A | |
BATTERY LOW | Relay contact output, OFF : Battery OK ; ON : Battery Low ; max. rating : 30V/1A | ||
Battery low voltage : < 11V | |||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70°C (Refer to "Derating Curve") | |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||
STORAGE TEMP., HUMIDITY | -40 ~ +85°C, 10 ~ 95% RH | ||
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) on CH1 output | ||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||
SAFETY &EMC(Note 5 | SAFETY STANDARDS | UL60950-1, TUV EN60950-1, EAC TP TC 004 approved | |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | ||
EMC EMISSION | Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 | ||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61204-3, light industry level, criteria A, EAC TP TC 020 ; meet EN54-4 for fire detection and fire alarm systems | ||
OTHERS | MTBF | 410.1K hrs min. MIL-HDBK-217F (25°C) | |
DIMENSION | 55*90*100mm (W*H*D) | ||
PACKING | 0.37Kg; 30pcs/12.1Kg/0.82CUFT | ||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 6. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. 7. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher °C°Cthan 2000m(6500ft). |